Verkauf durch Sack Fachmedien

Reimert

Protective Relaying for Power Generation Systems

Medium: Buch
ISBN: 978-0-8247-0700-2
Verlag: CRC Press
Erscheinungstermin: 09.12.2005
Lieferfrist: bis zu 10 Tage

Power outages have considerable social and economic impacts, and effective protection schemes are crucial to avoiding them. While most textbooks focus on the transmission and distribution aspects of protective relays, Protective Relaying for Power Generation Systems is the first to focus on protection of motors and generators from a power generation perspective. It also includes workbook constructions that allow students to perform protection-related calculations in Mathcad® and Excel®.

This text provides both a general overview and in-depth discussion of each topic, making it easy to tailor the material to students' needs. It also covers topics not found in other texts on the subject, including detailed time decrement generator fault calculations and minimum excitation limit. The author clearly explains the potential for damage and damaging mechanisms related to each protection function and includes thorough derivations of complex system interactions. Such derivations underlie the various rule-of-thumb setting criteria, provide insight into why the rules-of-thumb work and when they are not appropriate, and are useful for post-incident analysis. The book's flexible approach combines theoretical discussions with example settings that offer quick how-to information.

Protective Relaying for Power Generation Systems integrates fundamental knowledge with practical tools to ensure students have a thorough understanding of protection schemes and issues that arise during or after abnormal operation.


Produkteigenschaften


  • Artikelnummer: 9780824707002
  • Medium: Buch
  • ISBN: 978-0-8247-0700-2
  • Verlag: CRC Press
  • Erscheinungstermin: 09.12.2005
  • Sprache(n): Englisch
  • Auflage: 1. Auflage 2005
  • Serie: Power Engineering (Willis)
  • Produktform: Gebunden, HC gerader Rücken kaschiert
  • Gewicht: 1232 g
  • Seiten: 592
  • Format (B x H x T): 183 x 260 x 36 mm
  • Ausgabetyp: Kein, Unbekannt
Autoren/Hrsg.

Autoren

Generator Normal Operations. Generator Short Circuit Calculations. Generator Differential Relay: 87G. Backup Fault Protection. Generator Ground Fault Protection. Unbalanced Current Protection. Motoring Protection. Field Winding Protection. Overexcitation. Abnormal Frequency Protection. Minimum Excitation Limiter. Loss of Synchronism. Loss of Field Protection. Synchronization Protection. Accidental Energization Protection. Motor Protection. Appendix A: Swing Impedance Locus Calculation Using Excel®. Appendix B. Appendix C. Appendix D. Appendix E. Appendix F. Index.